IndustrialPCI (IPCI)
PCI=Peripheral Component Interconnect.
IndustrialPCI is a a version of PCI adapted for industrial and/or
embedded applications.
The IPCI connector has three parts:
    - Optional 60 pin PCI 64 bit extension (Top)
 
    - Mandatory 120 pin PCI 32 bit (Middle)
 
    - Optional 60 pin Custom I/O (Bottom)
 
 (At the backplane)
 (At the device (card))
UNKNOWN CONNECTOR at the backplane.
UNKNOWN CONNECTOR at the device (card).
System Slot (Middle)
    
        | Pin | 
        Name | 
        Description | 
        Note | 
    
    
        | A1 | 
        +3,3V | 
        +3.3 VDC | 
          | 
    
    
        | A2 | 
        AD2 | 
        Address 2 | 
          | 
    
    
        | A3 | 
        AD6 | 
        Address 6 | 
          | 
    
    
        | A4 | 
        GND | 
        Ground | 
          | 
    
    
        | A5 | 
        AD10 | 
        Address 10 | 
          | 
    
    
        | A6 | 
        AD13 | 
        Address 13 | 
          | 
    
    
        | A7 | 
        GND | 
        Ground | 
          | 
    
    
        | A8 | 
        SDONE | 
        Snoop Done | 
        1 | 
    
    
        | A9 | 
        GND | 
        Ground | 
          | 
    
    
        | A10 | 
        FRAME# | 
        Indicate Address or Data phase | 
        1 | 
    
    
        | A11 | 
        AD18 | 
        Address 18 | 
          | 
    
    
        | A12 | 
        GND | 
        Ground | 
          | 
    
    
        | A13 | 
        +5V | 
        +5 VDC | 
          | 
    
    
        | A14 | 
        AD24 | 
        Address 24 | 
          | 
    
    
        | A15 | 
        AD27 | 
        Address 27 | 
          | 
    
    
        | A16 | 
        GND | 
        Ground | 
          | 
    
    
        | A17 | 
        REQ2 | 
        Request 2 | 
        1 | 
    
    
        | A18 | 
        GND | 
        Ground | 
          | 
    
    
        | A19 | 
        CLK1 | 
        33 or 66 MHz Clock | 
          | 
    
    
        | A20 | 
        CLK2 | 
          | 
          | 
    
    
        | A21 | 
        GND | 
        Ground | 
          | 
    
    
        | A22 | 
        CLK3 | 
          | 
          | 
    
    
        | A23 | 
        CLK4 | 
          | 
          | 
    
    
        | A24 | 
        +3,3V | 
        +3.3 VDC | 
          | 
    
    
        | B1 | 
        REQ64# | 
        Request 64 ??? | 
        1 | 
    
    
        | B2 | 
        AD3 | 
        Address 3 | 
          | 
    
    
        | B3 | 
        +5V | 
        +5 VDC | 
          | 
    
    
        | B4 | 
        AD8 | 
        Address 8 | 
          | 
    
    
        | B5 | 
        +3,3V | 
        +3.3 VDC | 
          | 
    
    
        | B6 | 
        AD14 | 
        Address 14 | 
          | 
    
    
        | B7 | 
        PAR | 
        Parity | 
          | 
    
    
        | B8 | 
        +3,3V | 
        +3.3 VDC | 
          | 
    
    
        | B9 | 
        STOP# | 
        Stop | 
        1 | 
    
    
        | B10 | 
        C/BE2# | 
        Command, Byte Enable 2 | 
          | 
    
    
        | B11 | 
        V(I/O) | 
        +3.3 or +5 VDC | 
          | 
    
    
        | B12 | 
        AD21 | 
        Address 21 | 
          | 
    
    
        | B13 | 
        +3,3V | 
        +3.3 VDC | 
          | 
    
    
        | B14 | 
        V(I/O) | 
        +3.3 or +5 VDC | 
          | 
    
    
        | B15 | 
        AD28 | 
        Address 28 | 
          | 
    
    
        | B16 | 
        AD31 | 
        Address 31 | 
          | 
    
    
        | B17 | 
        +3,3V | 
        +3.3 VDC | 
          | 
    
    
        | B18 | 
        GNT3 | 
        Grant 3 | 
          | 
    
    
        | B19 | 
        RST# | 
        Reset | 
          | 
    
    
        | B20 | 
        NMI# | 
        Non Maskable Interrupt | 
          | 
    
    
        | B21 | 
        X6 | 
        Reserved (6) | 
          | 
    
    
        | B22 | 
        +5V | 
        +5 VDC | 
        : | 
    
    
        | B23 | 
        RSTIN# | 
          | 
        2 | 
    
    
        | B24 | 
        USB+ | 
        Universal Serial Bus (USB)(+) | 
          | 
    
    
        | C1 | 
        ACK64# | 
        Acknowledge 64 ??? | 
        1 | 
    
    
        | C2 | 
        GND | 
        Ground | 
          | 
    
    
        | C3 | 
        AD7 | 
        Address 7 | 
          | 
    
    
        | C4 | 
        AD9 | 
        Address 9 | 
          | 
    
    
        | C5 | 
        AD11 | 
        Address 11 | 
          | 
    
    
        | C6 | 
        GND | 
        Ground | 
          | 
    
    
        | C7 | 
        SERR# | 
        System Error | 
        1 | 
    
    
        | C8 | 
        PERR# | 
        Parity Error | 
        1 | 
    
    
        | C9 | 
        DEVSEL# | 
        Device Select | 
        1 | 
    
    
        | C10 | 
        GND | 
        Ground | 
          | 
    
    
        | C11 | 
        AD19 | 
        Address 19 | 
          | 
    
    
        | C12 | 
        AD22 | 
        Address 22 | 
          | 
    
    
        | C13 | 
        GND | 
        Ground | 
          | 
    
    
        | C14 | 
        AD25 | 
        Address 25 | 
          | 
    
    
        | C15 | 
        GND | 
        Ground | 
          | 
    
    
        | C16 | 
        X1 | 
        Reserved (1) | 
          | 
    
    
        | C17 | 
        GNT2 | 
        Grant 2 | 
          | 
    
    
        | C18 | 
        REQ4 | 
        Request 4 | 
        1 | 
    
    
        | C19 | 
        SLEEP#/SDAT | 
        Sleep/Serial Data (I2C) | 
        3 | 
    
    
        | C20 | 
        X4 | 
        Reserved (4) | 
          | 
    
    
        | C21 | 
        INTD# | 
        Interrupt D | 
        1 | 
    
    
        | C22 | 
        INTB# | 
        Interrupt B | 
        1 | 
    
    
        | C23 | 
        +5V | 
        +5 VDC | 
          | 
    
    
        | C24 | 
        USB- | 
        Universal Serial Bus (USB)(-) | 
          | 
    
    
        | D1 | 
        AD0 | 
        Address 0 | 
          | 
    
    
        | D2 | 
        AD4 | 
        Address 4 | 
          | 
    
    
        | D3 | 
        C/BE0# | 
        Command, Byte Enable 0 | 
          | 
    
    
        | D4 | 
        +3,3V | 
        +3.3 VDC | 
          | 
    
    
        | D5 | 
        AD12 | 
        Address 12 | 
          | 
    
    
        | D6 | 
        AD15 | 
        Address 15 | 
          | 
    
    
        | D7 | 
        V(I/O) | 
        +3.3 or +5 VDC | 
          | 
    
    
        | D8 | 
        LOCK# | 
        Resource Lock | 
        1 | 
    
    
        | D9 | 
        TRDY# | 
        Test Logic Ready | 
        1 | 
    
    
        | D10 | 
        AD16 | 
        Address 16 | 
          | 
    
    
        | D11 | 
        AD20 | 
        Address 20 | 
          | 
    
    
        | D12 | 
        +5V | 
        +5 VDC | 
          | 
    
    
        | D13 | 
        +5V | 
        +5 VDC | 
          | 
    
    
        | D14 | 
        AD26 | 
        Address 26 | 
          | 
    
    
        | D15 | 
        AD29 | 
        Address 29 | 
          | 
    
    
        | D16 | 
        REQ1 | 
        Request 1 | 
        1 | 
    
    
        | D17 | 
        REQ3 | 
        Request 3 | 
        1 | 
    
    
        | D18 | 
        V(I/O) | 
        +3.3 or +5 VDC | 
          | 
    
    
        | D19 | 
        X2 | 
        Reserved (2) | 
          | 
    
    
        | D20 | 
        X5 | 
        Reserved (5) | 
          | 
    
    
        | D21 | 
        +3,3V | 
        +3.3 VDC | 
          | 
    
    
        | D22 | 
        INTA# | 
        Interrupt A | 
        1 | 
    
    
        | D23 | 
        ICPEN#/SCLK | 
        ICPEN/Serial Clock (I2C) | 
        3 | 
    
    
        | D24 | 
        OSC (PWDN) | 
          | 
          | 
    
    
        | E1 | 
        AD1 | 
        Address 1 | 
          | 
    
    
        | E2 | 
        AD5 | 
        Address 5 | 
          | 
    
    
        | E3 | 
        GND | 
        Ground | 
          | 
    
    
        | E4 | 
        M66EN | 
        Enable 66Mhz PCI-bus | 
          | 
    
    
        | E5 | 
        GND | 
        Ground | 
          | 
    
    
        | E6 | 
        C/BE1# | 
        Command, Byte Enable 1 | 
          | 
    
    
        | E7 | 
        SBO# | 
        Snoop Backoff | 
        1 | 
    
    
        | E8 | 
        +5V | 
        +5 VDC | 
          | 
    
    
        | E9 | 
        IRDY# | 
        Initatior Ready | 
        1 | 
    
    
        | E10 | 
        AD17 | 
        Address 17 | 
          | 
    
    
        | E11 | 
        GND | 
        Ground | 
          | 
    
    
        | E12 | 
        AD23 | 
        Address 23 | 
          | 
    
    
        | E13 | 
        C/BE3# | 
        Command, Byte Enable 3 | 
          | 
    
    
        | E14 | 
        GND | 
        Ground | 
          | 
    
    
        | E15 | 
        AD30 | 
        Address 30 | 
          | 
    
    
        | E16 | 
        GNT1 | 
        Grant 1 | 
          | 
    
    
        | E17 | 
        +5V | 
        +5 VDC | 
          | 
    
    
        | E18 | 
        GNT4 | 
        Grant 4 | 
          | 
    
    
        | E19 | 
        X3 | 
        Reserved (3) | 
          | 
    
    
        | E20 | 
        GND | 
        Ground | 
          | 
    
    
        | E21 | 
        INTC# | 
        Interrupt C | 
        1 | 
    
    
        | E22 | 
        -12V | 
        -12 VDC | 
          | 
    
    
        | E23 | 
        +12V | 
        +12 VDC | 
          | 
    
    
        | E24 | 
        VBATT | 
          | 
          | 
    
1 = Pullup resistor of 2,7 kW on the System Slot (CPU).
2 = Pullup resistor of 330 W on the System Slot (CPU).
3 = Pullup resistor of 4,7 kW, if not supported by the System
Slot (CPU).
Module Bus Slot (Middle)
    
        | Pin | 
        Name | 
        Description | 
        Note | 
    
    
        | A1 | 
        +3,3V | 
        +3.3 VDC | 
          | 
    
    
        | A2 | 
        AD2 | 
        Address 2 | 
          | 
    
    
        | A3 | 
        AD6 | 
        Address 6 | 
          | 
    
    
        | A4 | 
        GND | 
        Ground | 
          | 
    
    
        | A5 | 
        AD10 | 
        Address 10 | 
          | 
    
    
        | A6 | 
        AD13 | 
        Address 13 | 
          | 
    
    
        | A7 | 
        GND | 
        Ground | 
          | 
    
    
        | A8 | 
        SDONE | 
        Snoop Done | 
        1 | 
    
    
        | A9 | 
        GND | 
        Ground | 
          | 
    
    
        | A10 | 
        FRAME# | 
        Indicate Address or Data phase | 
        1 | 
    
    
        | A11 | 
        AD18 | 
        Address 18 | 
          | 
    
    
        | A12 | 
        GND | 
        Ground | 
          | 
    
    
        | A13 | 
        +5V | 
        +5 VDC | 
          | 
    
    
        | A14 | 
        AD24 | 
        Address 24 | 
          | 
    
    
        | A15 | 
        AD27 | 
        Address 27 | 
          | 
    
    
        | A16 | 
        GND | 
        Ground | 
          | 
    
    
        | A17 | 
        REQ2 | 
        Request 2 | 
        1 | 
    
    
        | A18 | 
        CLKM | 
          | 
          | 
    
    
        | A19 | 
        CLK1 | 
        33 or 66 MHz Clock | 
          | 
    
    
        | A20 | 
        CLK2 | 
          | 
          | 
    
    
        | A21 | 
        GND | 
        Ground | 
          | 
    
    
        | A22 | 
        CLK3 | 
          | 
          | 
    
    
        | A23 | 
        CLK4 | 
          | 
          | 
    
    
        | A24 | 
        +3,3V | 
        +3.3 VDC | 
          | 
    
    
        | B1 | 
        REQ64# | 
        Request 64 ??? | 
        1 | 
    
    
        | B2 | 
        AD3 | 
        Address 3 | 
          | 
    
    
        | B3 | 
        +5V | 
        +5 VDC | 
          | 
    
    
        | B4 | 
        AD8 | 
        Address 8 | 
          | 
    
    
        | B5 | 
        +3,3V | 
        +3.3 VDC | 
          | 
    
    
        | B6 | 
        AD14 | 
        Address 14 | 
          | 
    
    
        | B7 | 
        PAR | 
        Parity | 
          | 
    
    
        | B8 | 
        +3,3V | 
        +3.3 VDC | 
          | 
    
    
        | B9 | 
        STOP# | 
        Stop | 
        1 | 
    
    
        | B10 | 
        C/BE2# | 
        Command, Byte Enable 2 | 
          | 
    
    
        | B11 | 
        V(I/O) | 
        +3.3 or +5 VDC | 
          | 
    
    
        | B12 | 
        AD21 | 
        Address 21 | 
          | 
    
    
        | B13 | 
        +3,3V | 
        +3.3 VDC | 
          | 
    
    
        | B14 | 
        V(I/O) | 
        +3.3 or +5 VDC | 
          | 
    
    
        | B15 | 
        AD28 | 
        Address 28 | 
          | 
    
    
        | B16 | 
        AD31 | 
        Address 31 | 
          | 
    
    
        | B17 | 
        +3,3V | 
        +3.3 VDC | 
          | 
    
    
        | B18 | 
        GNT3 | 
        Grant 3 | 
          | 
    
    
        | B19 | 
        RST# | 
        Reset | 
          | 
    
    
        | B20 | 
        NMI# | 
        Non Maskable Interrupt | 
          | 
    
    
        | B21 | 
        X6 | 
        Reserved (6) | 
          | 
    
    
        | B22 | 
        +5V | 
        +5 VDC | 
        : | 
    
    
        | B23 | 
        RSTIN# | 
          | 
          | 
    
    
        | B24 | 
        USB+ | 
        Universal Serial Bus (USB)(+) | 
          | 
    
    
        | C1 | 
        ACK64# | 
        Acknowledge 64 ??? | 
        1 | 
    
    
        | C2 | 
        GND | 
        Ground | 
          | 
    
    
        | C3 | 
        AD7 | 
        Address 7 | 
          | 
    
    
        | C4 | 
        AD9 | 
        Address 9 | 
          | 
    
    
        | C5 | 
        AD11 | 
        Address 11 | 
          | 
    
    
        | C6 | 
        GND | 
        Ground | 
          | 
    
    
        | C7 | 
        SERR# | 
        System Error | 
        1 | 
    
    
        | C8 | 
        PERR# | 
        Parity Error | 
        1 | 
    
    
        | C9 | 
        DEVSEL# | 
        Device Select | 
        1 | 
    
    
        | C10 | 
        GND | 
        Ground | 
          | 
    
    
        | C11 | 
        AD19 | 
        Address 19 | 
          | 
    
    
        | C12 | 
        AD22 | 
        Address 22 | 
          | 
    
    
        | C13 | 
        GND | 
        Ground | 
          | 
    
    
        | C14 | 
        AD25 | 
        Address 25 | 
          | 
    
    
        | C15 | 
        GND | 
        Ground | 
          | 
    
    
        | C16 | 
        X1 | 
        Reserved (1) | 
          | 
    
    
        | C17 | 
        GNT2 | 
        Grant 2 | 
          | 
    
    
        | C18 | 
        REQ4 | 
        Request 4 | 
        1 | 
    
    
        | C19 | 
        SLEEP#/SDAT | 
        Sleep/Serial Data (I2C) | 
          | 
    
    
        | C20 | 
        X4 | 
        Reserved (4) | 
          | 
    
    
        | C21 | 
        INTD# | 
        Interrupt D | 
        1 | 
    
    
        | C22 | 
        INTB# | 
        Interrupt B | 
        1 | 
    
    
        | C23 | 
        +5V | 
        +5 VDC | 
          | 
    
    
        | C24 | 
        USB- | 
        Universal Serial Bus (USB)(-) | 
          | 
    
    
        | D1 | 
        AD0 | 
        Address 0 | 
          | 
    
    
        | D2 | 
        AD4 | 
        Address 4 | 
          | 
    
    
        | D3 | 
        C/BE0# | 
        Command, Byte Enable 0 | 
          | 
    
    
        | D4 | 
        +3,3V | 
        +3.3 VDC | 
          | 
    
    
        | D5 | 
        AD12 | 
        Address 12 | 
          | 
    
    
        | D6 | 
        AD15 | 
        Address 15 | 
          | 
    
    
        | D7 | 
        V(I/O) | 
        +3.3 or +5 VDC | 
          | 
    
    
        | D8 | 
        LOCK# | 
        Resource Lock | 
        1 | 
    
    
        | D9 | 
        TRDY# | 
        Test Logic Ready | 
        1 | 
    
    
        | D10 | 
        AD16 | 
        Address 16 | 
          | 
    
    
        | D11 | 
        AD20 | 
        Address 20 | 
          | 
    
    
        | D12 | 
        +5V | 
        +5 VDC | 
          | 
    
    
        | D13 | 
        +5V | 
        +5 VDC | 
          | 
    
    
        | D14 | 
        AD26 | 
        Address 26 | 
          | 
    
    
        | D15 | 
        AD29 | 
        Address 29 | 
          | 
    
    
        | D16 | 
        REQ1 | 
        Request 1 | 
        1 | 
    
    
        | D17 | 
        REQ3 | 
        Request 3 | 
        1 | 
    
    
        | D18 | 
        V(I/O) | 
        +3.3 or +5 VDC | 
          | 
    
    
        | D19 | 
        X2 | 
        Reserved (2) | 
          | 
    
    
        | D20 | 
        X5 | 
        Reserved (5) | 
          | 
    
    
        | D21 | 
        +3,3V | 
        +3.3 VDC | 
          | 
    
    
        | D22 | 
        INTA# | 
        Interrupt A | 
        1 | 
    
    
        | D23 | 
        ICPEN#/SCLK | 
        ICPEN/Serial Clock (I2C) | 
        3 | 
    
    
        | D24 | 
        OSC (PWDN) | 
          | 
          | 
    
    
        | E1 | 
        AD1 | 
        Address 1 | 
          | 
    
    
        | E2 | 
        AD5 | 
        Address 5 | 
          | 
    
    
        | E3 | 
        GND | 
        Ground | 
          | 
    
    
        | E4 | 
        M66EN | 
        Enable 66Mhz PCI-bus | 
          | 
    
    
        | E5 | 
        GND | 
        Ground | 
          | 
    
    
        | E6 | 
        C/BE1# | 
        Command, Byte Enable 1 | 
          | 
    
    
        | E7 | 
        SBO# | 
        Snoop Backoff | 
        1 | 
    
    
        | E8 | 
        +5V | 
        +5 VDC | 
          | 
    
    
        | E9 | 
        IRDY# | 
        Initatior Ready | 
        1 | 
    
    
        | E10 | 
        AD17 | 
        Address 17 | 
          | 
    
    
        | E11 | 
        GND | 
        Ground | 
          | 
    
    
        | E12 | 
        AD23 | 
        Address 23 | 
          | 
    
    
        | E13 | 
        C/BE3# | 
        Command, Byte Enable 3 | 
          | 
    
    
        | E14 | 
        GND | 
        Ground | 
          | 
    
    
        | E15 | 
        AD30 | 
        Address 30 | 
          | 
    
    
        | E16 | 
        GNT1 | 
        Grant 1 | 
          | 
    
    
        | E17 | 
        +5V | 
        +5 VDC | 
          | 
    
    
        | E18 | 
        GNT4 | 
        Grant 4 | 
          | 
    
    
        | E19 | 
        X3 | 
        Reserved (3) | 
          | 
    
    
        | E20 | 
        GND | 
        Ground | 
          | 
    
    
        | E21 | 
        INTC# | 
        Interrupt C | 
        1 | 
    
    
        | E22 | 
        -12V | 
        -12 VDC | 
          | 
    
    
        | E23 | 
        +12V | 
        +12 VDC | 
          | 
    
    
        | E24 | 
        VBATT | 
          | 
          | 
    
1 = Pullup resistor of 2,7 kW on the System Slot (CPU).
Card Slot (Middle)
    
        | Pin | 
        Name | 
        Description | 
        Note | 
    
    
        | A1 | 
        +3,3V | 
        +3.3 VDC | 
          | 
    
    
        | A2 | 
        AD2 | 
        Address 2 | 
          | 
    
    
        | A3 | 
        AD6 | 
        Address 6 | 
          | 
    
    
        | A4 | 
        GND | 
        Ground | 
          | 
    
    
        | A5 | 
        AD10 | 
        Address 10 | 
          | 
    
    
        | A6 | 
        AD13 | 
        Address 13 | 
          | 
    
    
        | A7 | 
        GND | 
        Ground | 
          | 
    
    
        | A8 | 
        SDONE | 
        Snoop Done | 
        1 | 
    
    
        | A9 | 
        GND | 
        Ground | 
          | 
    
    
        | A10 | 
        FRAME# | 
        Indicate Address or Data phase | 
        1 | 
    
    
        | A11 | 
        AD18 | 
        Address 18 | 
          | 
    
    
        | A12 | 
        GND | 
        Ground | 
          | 
    
    
        | A13 | 
        +5V | 
        +5 VDC | 
          | 
    
    
        | A14 | 
        AD24 | 
        Address 24 | 
          | 
    
    
        | A15 | 
        AD27 | 
        Address 27 | 
          | 
    
    
        | A16 | 
        GND | 
        Ground | 
          | 
    
    
        | A17 | 
        IDSEL0 | 
        IDSEL0 | 
        1 | 
    
    
        | A18 | 
        GND | 
        Ground | 
          | 
    
    
        | A19 | 
        CLK1 | 
        33 or 66 MHz Clock | 
          | 
    
    
        | A20 | 
        GND | 
        Ground | 
          | 
    
    
        | A21 | 
        GND | 
        Ground | 
          | 
    
    
        | A22 | 
        GND | 
        Ground | 
          | 
    
    
        | A23 | 
        GND | 
        Ground | 
          | 
    
    
        | A24 | 
        +3,3V | 
        +3.3 VDC | 
          | 
    
    
        | B1 | 
        REQ64# | 
        Request 64 ??? | 
        1 | 
    
    
        | B2 | 
        AD3 | 
        Address 3 | 
          | 
    
    
        | B3 | 
        +5V | 
        +5 VDC | 
          | 
    
    
        | B4 | 
        AD8 | 
        Address 8 | 
          | 
    
    
        | B5 | 
        +3,3V | 
        +3.3 VDC | 
          | 
    
    
        | B6 | 
        AD14 | 
        Address 14 | 
          | 
    
    
        | B7 | 
        PAR | 
        Parity | 
          | 
    
    
        | B8 | 
        +3,3V | 
        +3.3 VDC | 
          | 
    
    
        | B9 | 
        STOP# | 
        Stop | 
        1 | 
    
    
        | B10 | 
        C/BE2# | 
        Command, Byte Enable 2 | 
          | 
    
    
        | B11 | 
        V(I/O) | 
        +3.3 or +5 VDC | 
          | 
    
    
        | B12 | 
        AD21 | 
        Address 21 | 
          | 
    
    
        | B13 | 
        +3,3V | 
        +3.3 VDC | 
          | 
    
    
        | B14 | 
        V(I/O) | 
        +3.3 or +5 VDC | 
          | 
    
    
        | B15 | 
        AD28 | 
        Address 28 | 
          | 
    
    
        | B16 | 
        AD31 | 
        Address 31 | 
          | 
    
    
        | B17 | 
        +3,3V | 
        +3.3 VDC | 
          | 
    
    
        | B18 | 
        GND | 
        Ground | 
          | 
    
    
        | B19 | 
        RST# | 
        Reset | 
          | 
    
    
        | B20 | 
        NMI# | 
        Non Maskable Interrupt | 
          | 
    
    
        | B21 | 
        X6 | 
        Reserved (6) | 
          | 
    
    
        | B22 | 
        +5V | 
        +5 VDC | 
        : | 
    
    
        | B23 | 
        RSTIN# | 
          | 
          | 
    
    
        | B24 | 
        USB+ | 
        Universal Serial Bus (USB)(+) | 
          | 
    
    
        | C1 | 
        ACK64# | 
        Acknowledge 64 ??? | 
        1 | 
    
    
        | C2 | 
        GND | 
        Ground | 
          | 
    
    
        | C3 | 
        AD7 | 
        Address 7 | 
          | 
    
    
        | C4 | 
        AD9 | 
        Address 9 | 
          | 
    
    
        | C5 | 
        AD11 | 
        Address 11 | 
          | 
    
    
        | C6 | 
        GND | 
        Ground | 
          | 
    
    
        | C7 | 
        SERR# | 
        System Error | 
        1 | 
    
    
        | C8 | 
        PERR# | 
        Parity Error | 
        1 | 
    
    
        | C9 | 
        DEVSEL# | 
        Device Select | 
        1 | 
    
    
        | C10 | 
        GND | 
        Ground | 
          | 
    
    
        | C11 | 
        AD19 | 
        Address 19 | 
          | 
    
    
        | C12 | 
        AD22 | 
        Address 22 | 
          | 
    
    
        | C13 | 
        GND | 
        Ground | 
          | 
    
    
        | C14 | 
        AD25 | 
        Address 25 | 
          | 
    
    
        | C15 | 
        GND | 
        Ground | 
          | 
    
    
        | C16 | 
        X1 | 
        Reserved (1) | 
          | 
    
    
        | C17 | 
        IDSEL1 | 
        Initialization Device Select 1 | 
          | 
    
    
        | C18 | 
        GND | 
        Ground | 
          | 
    
    
        | C19 | 
        SLEEP#/SDAT | 
        Sleep/Serial Data (I2C) | 
          | 
    
    
        | C20 | 
        X4 | 
        Reserved (4) | 
          | 
    
    
        | C21 | 
        INTD# | 
        Interrupt D | 
        1 | 
    
    
        | C22 | 
        INTB# | 
        Interrupt B | 
        1 | 
    
    
        | C23 | 
        +5V | 
        +5 VDC | 
          | 
    
    
        | C24 | 
        USB- | 
        Universal Serial Bus (USB)(-) | 
          | 
    
    
        | D1 | 
        AD0 | 
        Address 0 | 
          | 
    
    
        | D2 | 
        AD4 | 
        Address 4 | 
          | 
    
    
        | D3 | 
        C/BE0# | 
        Command, Byte Enable 0 | 
          | 
    
    
        | D4 | 
        +3,3V | 
        +3.3 VDC | 
          | 
    
    
        | D5 | 
        AD12 | 
        Address 12 | 
          | 
    
    
        | D6 | 
        AD15 | 
        Address 15 | 
          | 
    
    
        | D7 | 
        V(I/O) | 
        +3.3 or +5 VDC | 
          | 
    
    
        | D8 | 
        LOCK# | 
        Resource Lock | 
        1 | 
    
    
        | D9 | 
        TRDY# | 
        Test Logic Ready | 
        1 | 
    
    
        | D10 | 
        AD16 | 
        Address 16 | 
          | 
    
    
        | D11 | 
        AD20 | 
        Address 20 | 
          | 
    
    
        | D12 | 
        +5V | 
        +5 VDC | 
          | 
    
    
        | D13 | 
        +5V | 
        +5 VDC | 
          | 
    
    
        | D14 | 
        AD26 | 
        Address 26 | 
          | 
    
    
        | D15 | 
        AD29 | 
        Address 29 | 
          | 
    
    
        | D16 | 
        REQ1 | 
        Request 1 | 
        1 | 
    
    
        | D17 | 
        IDSEL2 | 
        Initialization Device Select 2 | 
          | 
    
    
        | D18 | 
        V(I/O) | 
        +3.3 or +5 VDC | 
          | 
    
    
        | D19 | 
        X2 | 
        Reserved (2) | 
          | 
    
    
        | D20 | 
        X5 | 
        Reserved (5) | 
          | 
    
    
        | D21 | 
        +3,3V | 
        +3.3 VDC | 
          | 
    
    
        | D22 | 
        INTA# | 
        Interrupt A | 
        1 | 
    
    
        | D23 | 
        ICPEN#/SCLK | 
        ICPEN/Serial Clock (I2C) | 
        3 | 
    
    
        | D24 | 
        OSC (PWDN) | 
          | 
          | 
    
    
        | E1 | 
        AD1 | 
        Address 1 | 
          | 
    
    
        | E2 | 
        AD5 | 
        Address 5 | 
          | 
    
    
        | E3 | 
        GND | 
        Ground | 
          | 
    
    
        | E4 | 
        M66EN | 
        Enable 66Mhz PCI-bus | 
          | 
    
    
        | E5 | 
        GND | 
        Ground | 
          | 
    
    
        | E6 | 
        C/BE1# | 
        Command, Byte Enable 1 | 
          | 
    
    
        | E7 | 
        SBO# | 
        Snoop Backoff | 
        1 | 
    
    
        | E8 | 
        +5V | 
        +5 VDC | 
          | 
    
    
        | E9 | 
        IRDY# | 
        Initatior Ready | 
        1 | 
    
    
        | E10 | 
        AD17 | 
        Address 17 | 
          | 
    
    
        | E11 | 
        GND | 
        Ground | 
          | 
    
    
        | E12 | 
        AD23 | 
        Address 23 | 
          | 
    
    
        | E13 | 
        C/BE3# | 
        Command, Byte Enable 3 | 
          | 
    
    
        | E14 | 
        GND | 
        Ground | 
          | 
    
    
        | E15 | 
        AD30 | 
        Address 30 | 
          | 
    
    
        | E16 | 
        GNT1 | 
        Grant 1 | 
          | 
    
    
        | E17 | 
        +5V | 
        +5 VDC | 
          | 
    
    
        | E18 | 
        GNT4 | 
        Grant 4 | 
          | 
    
    
        | E19 | 
        X3 | 
        Reserved (3) | 
          | 
    
    
        | E20 | 
        GND | 
        Ground | 
          | 
    
    
        | E21 | 
        INTC# | 
        Interrupt C | 
        1 | 
    
    
        | E22 | 
        -12V | 
        -12 VDC | 
          | 
    
    
        | E23 | 
        +12V | 
        +12 VDC | 
          | 
    
    
        | E24 | 
        VBATT | 
          | 
          | 
    
1 = Pullup resistor of 2,7 kW on the System Slot (CPU).
64-bit PCI (Top)
    
        | Pin | 
        Name | 
        Description | 
        Note | 
    
    
        | A1 | 
        GND | 
        Ground | 
          | 
    
    
        | A2 | 
        X10 | 
        Reserved (10) | 
          | 
    
    
        | A3 | 
        AD35 | 
        Address 35 | 
        2 | 
    
    
        | A4 | 
        AD38 | 
        Address 38 | 
        2 | 
    
    
        | A5 | 
        AD42 | 
        Address 42 | 
        2 | 
    
    
        | A6 | 
        V(I/O) | 
        +3.3 or +5 VDC | 
          | 
    
    
        | A7 | 
        V(I/O) | 
        +3.3 or +5 VDC | 
          | 
    
    
        | A8 | 
        AD52 | 
        Address 52 | 
        2 | 
    
    
        | A9 | 
        AD56 | 
        Address 56 | 
        2 | 
    
    
        | A10 | 
        AD60 | 
        Address 60 | 
        2 | 
    
    
        | A11 | 
        AD63 | 
        Address 63 | 
        2 | 
    
    
        | A12 | 
        GND | 
        Ground | 
          | 
    
    
        | B1 | 
        X7 | 
        Reserved (7) | 
          | 
    
    
        | B2 | 
        GND | 
        Ground | 
          | 
    
    
        | B3 | 
        AD36 | 
        Address 36 | 
        2 | 
    
    
        | B4 | 
        AD39 | 
        Address 39 | 
        2 | 
    
    
        | B5 | 
        AD43 | 
        Address 43 | 
        2 | 
    
    
        | B6 | 
        AD46 | 
        Address 46 | 
        2 | 
    
    
        | B7 | 
        AD49 | 
        Address 49 | 
        2 | 
    
    
        | B8 | 
        AD53 | 
        Address 53 | 
        2 | 
    
    
        | B9 | 
        AD57 | 
        Address 57 | 
        2 | 
    
    
        | B10 | 
        AD61 | 
        Address 61 | 
        2 | 
    
    
        | B11 | 
        GND | 
        Ground | 
          | 
    
    
        | B12 | 
        C/BE6# | 
        Command, Byte Enable 6 | 
        2 | 
    
    
        | C1 | 
        X8 | 
        Reserved (8) | 
          | 
    
    
        | C2 | 
        AD32 | 
        Address 32 | 
        2 | 
    
    
        | C3 | 
        GND | 
        Ground | 
          | 
    
    
        | C4 | 
        AD40 | 
        Address 40 | 
        2 | 
    
    
        | C5 | 
        AD44 | 
        Address 44 | 
        2 | 
    
    
        | C6 | 
        GND | 
        Ground | 
          | 
    
    
        | C7 | 
        GND | 
        Ground | 
          | 
    
    
        | C8 | 
        AD54 | 
        Address 54 | 
        2 | 
    
    
        | C9 | 
        AD58 | 
        Address 58 | 
        2 | 
    
    
        | C10 | 
        GND | 
        Ground | 
          | 
    
    
        | C11 | 
        PAR64 | 
        Parity 64 ??? | 
        2 | 
    
    
        | C12 | 
        C/BE7# | 
        Command, Byte Enable 7 | 
        2 | 
    
    
        | D1 | 
        X9 | 
        Reserved (9) | 
          | 
    
    
        | D2 | 
        AD33 | 
        Address 33 | 
        2 | 
    
    
        | D3 | 
        AD37 | 
        Address 37 | 
        2 | 
    
    
        | D4 | 
        GND | 
        Ground | 
          | 
    
    
        | D5 | 
        AD45 | 
        Address 45 | 
        2 | 
    
    
        | D6 | 
        AD47 | 
        Address 47 | 
        2 | 
    
    
        | D7 | 
        AD50 | 
        Address 50 | 
        2 | 
    
    
        | D8 | 
        AD55 | 
        Address 55 | 
        2 | 
    
    
        | D9 | 
        GND | 
        Ground | 
          | 
    
    
        | D10 | 
        AD62 | 
        Address 62 | 
        2 | 
    
    
        | D11 | 
        C/BE4# | 
        Command, Byte Enable 4 | 
        2 | 
    
    
        | D12 | 
        X11 | 
        Reserved (11) | 
          | 
    
    
        | E1 | 
        GND | 
        Ground | 
          | 
    
    
        | E2 | 
        AD34 | 
        Address 34 | 
        2 | 
    
    
        | E3 | 
        V(I/O) | 
        +3.3 or +5 VDC | 
          | 
    
    
        | E4 | 
        AD41 | 
        Address 41 | 
        2 | 
    
    
        | E5 | 
        GND | 
        Ground | 
          | 
    
    
        | E6 | 
        AD48 | 
        Address 48 | 
        2 | 
    
    
        | E7 | 
        AD51 | 
        Address 51 | 
        2 | 
    
    
        | E8 | 
        GND | 
        Ground | 
          | 
    
    
        | E9 | 
        AD59 | 
        Address 59 | 
        2 | 
    
    
        | E10 | 
        V(I/O) | 
        +3.3 or +5 VDC | 
          | 
    
    
        | E11 | 
        C/BE5# | 
        Command, Byte Enable 5 | 
        2 | 
    
    
        | E12 | 
        X12 | 
        Reserved (12) | 
          | 
    
2 = Pullup resistor of 2,7 kW (5V bus system) or 8,2 kW (3,3V
bus system) on the backplane.
ISA96/AT96 (Bottom)
    
        | Pin | 
        Name | 
        Description | 
        Note | 
    
    
        | A1 | 
        RSTDRV | 
          | 
          | 
    
    
        | A2 | 
        IRQ9 | 
        Interrupt 9 | 
          | 
    
    
        | A3 | 
        SD11 | 
        Data 11 | 
          | 
    
    
        | A4 | 
        SD9 | 
        Data 9 | 
          | 
    
    
        | A5 | 
        IOCHRDY | 
          | 
        1 | 
    
    
        | A6 | 
        IOW# | 
        I/O Write | 
          | 
    
    
        | A7 | 
        SA15 | 
        Address 15 | 
          | 
    
    
        | A8 | 
        CLK | 
        Clock | 
          | 
    
    
        | A9 | 
        SA10 | 
        Address 10 | 
          | 
    
    
        | A10 | 
        SA7 | 
        Address 7 | 
          | 
    
    
        | A11 | 
        T/C | 
          | 
          | 
    
    
        | A12 | 
        SA2 | 
        Address 2 | 
          | 
    
    
        | B1 | 
        SD15 | 
        Data 15 | 
          | 
    
    
        | B2 | 
        SD13 | 
        Data 13 | 
          | 
    
    
        | B3 | 
        SD3 | 
        Data 3 | 
          | 
    
    
        | B4 | 
        SD1 | 
        Data 1 | 
          | 
    
    
        | B5 | 
        SMEMW# | 
        System Memory Write | 
          | 
    
    
        | B6 | 
        SA18 | 
        Address 18 | 
          | 
    
    
        | B7 | 
        SA14 | 
        Address 14 | 
          | 
    
    
        | B8 | 
        DACK6# | 
        DMA Acknowledge 6 | 
          | 
    
    
        | B9 | 
        SA9 | 
        Address 9 | 
          | 
    
    
        | B10 | 
        IRQ3 | 
        Interrupt 3 | 
          | 
    
    
        | B11 | 
        IOCS16# | 
        I/O 16-bit chip select | 
        1 | 
    
    
        | B12 | 
        SA1 | 
        Address 1 | 
          | 
    
    
        | C1 | 
        SD7 | 
        Data 7 | 
          | 
    
    
        | C2 | 
        SD5 | 
        Data 5 | 
          | 
    
    
        | C3 | 
        SD10 | 
        Data 10 | 
          | 
    
    
        | C4 | 
        SD8 | 
        Data 8 | 
          | 
    
    
        | C5 | 
        AEN | 
        Address Enable | 
          | 
    
    
        | C6 | 
        IOR# | 
        I/O Read | 
          | 
    
    
        | C7 | 
        SA13 | 
        Address 13 | 
          | 
    
    
        | C8 | 
        SA11 | 
        Address 11 | 
          | 
    
    
        | C9 | 
        IRQ5 | 
        Interrupt 5 | 
          | 
    
    
        | C10 | 
        SA6 | 
        Address 6 | 
          | 
    
    
        | C11 | 
        SA4 | 
        Address 4 | 
          | 
    
    
        | C12 | 
        IRQ11 | 
        Interrupt 11 | 
          | 
    
    
        | D1 | 
        SD14 | 
        Data 14 | 
          | 
    
    
        | D2 | 
        SD12 | 
        Data 12 | 
          | 
    
    
        | D3 | 
        SD2 | 
        Data 2 | 
          | 
    
    
        | D4 | 
        SD0 | 
        Data 0 | 
          | 
    
    
        | D5 | 
        SMEMR# | 
        System Memory Read | 
          | 
    
    
        | D6 | 
        SA17 | 
        Address 17 | 
          | 
    
    
        | D7 | 
        REF# | 
          | 
          | 
    
    
        | D8 | 
        IRQ7 | 
        Interrupt 7 | 
          | 
    
    
        | D9 | 
        SA8 | 
        Address 8 | 
          | 
    
    
        | D10 | 
        MCS16# | 
          | 
        1 | 
    
    
        | D11 | 
        BALE | 
          | 
          | 
    
    
        | D12 | 
        SA0 | 
        Address 0 | 
          | 
    
    
        | E1 | 
        SD6 | 
        Data 6 | 
          | 
    
    
        | E2 | 
        SD4 | 
        Data 4 | 
          | 
    
    
        | E3 | 
        0WS | 
          | 
        1 | 
    
    
        | E4 | 
        SBHE# | 
          | 
          | 
    
    
        | E5 | 
        SA19 | 
        Address 19 | 
          | 
    
    
        | E6 | 
        SA16 | 
        Address 16 | 
          | 
    
    
        | E7 | 
        SA12 | 
        Address 12 | 
          | 
    
    
        | E8 | 
        DRQ6 | 
        DMA Request 6 | 
          | 
    
    
        | E9 | 
        IRQ4 | 
        Interrupt 4 | 
          | 
    
    
        | E10 | 
        SA5 | 
        Address 5 | 
          | 
    
    
        | E11 | 
        SA3 | 
        Address 3 | 
          | 
    
    
        | E12 | 
        IRQ10 | 
        Interrupt 10 | 
          | 
    
1 = Pullup resistor must be integrated into the System Slot
(CPU).
VMEbus (Bottom)
    
        | Pin | 
        Name | 
        Description | 
    
    
        | A1 | 
        D0 | 
        Data 0 | 
    
    
        | A2 | 
        D2 | 
        Data 2 | 
    
    
        | A3 | 
        D12 | 
        Data 12 | 
    
    
        | A4 | 
        D7 | 
        Data 7 | 
    
    
        | A5 | 
        DS1# | 
          | 
    
    
        | A6 | 
        BR3# | 
          | 
    
    
        | A7 | 
        AM1 | 
          | 
    
    
        | A8 | 
        AM3 | 
          | 
    
    
        | A9 | 
        IACKOUT# | 
          | 
    
    
        | A10 | 
        A14 | 
        Address 14 | 
    
    
        | A11 | 
        A12 | 
        Address 12 | 
    
    
        | A12 | 
        A10 | 
        Address 10 | 
    
    
        | B1 | 
        BBSY# | 
          | 
    
    
        | B2 | 
        D10 | 
        Data 10 | 
    
    
        | B3 | 
        D5 | 
        Data 5 | 
    
    
        | B4 | 
        D15 | 
        Data 15 | 
    
    
        | B5 | 
        SYSRES# | 
          | 
    
    
        | B6 | 
        A23 | 
        Address 23 | 
    
    
        | B7 | 
        A21 | 
        Address 21 | 
    
    
        | B8 | 
        A19 | 
        Address 19 | 
    
    
        | B9 | 
        A16 | 
        Address 16 | 
    
    
        | B10 | 
        A6 | 
        Address 6 | 
    
    
        | B11 | 
        A4 | 
        Address 4 | 
    
    
        | B12 | 
        A2 | 
        Address 2 | 
    
    
        | C1 | 
        D8 | 
        Data 8 | 
    
    
        | C2 | 
        D3 | 
        Data 3 | 
    
    
        | C3 | 
        D13 | 
        Data 13 | 
    
    
        | C4 | 
        SYSCLK | 
          | 
    
    
        | C5 | 
        DS0# | 
          | 
    
    
        | C6 | 
        DTACK# | 
          | 
    
    
        | C7 | 
        AS# | 
          | 
    
    
        | C8 | 
        IACK# | 
          | 
    
    
        | C9 | 
        AM4 | 
          | 
    
    
        | C10 | 
        A13 | 
        Address 13 | 
    
    
        | C11 | 
        A11 | 
        Address 11 | 
    
    
        | C12 | 
        A9 | 
        Address 9 | 
    
    
        | D1 | 
        D1 | 
        Data 1 | 
    
    
        | D2 | 
        D11 | 
        Data 11 | 
    
    
        | D3 | 
        D6 | 
        Data 6 | 
    
    
        | D4 | 
        BG3OUT# | 
          | 
    
    
        | D5 | 
        WR# | 
        Write | 
    
    
        | D6 | 
        AM0 | 
          | 
    
    
        | D7 | 
        AM2 | 
          | 
    
    
        | D8 | 
        A18 | 
        Address 18 | 
    
    
        | D9 | 
        A15 | 
        Address 15 | 
    
    
        | D10 | 
        A5 | 
        Address 5 | 
    
    
        | D11 | 
        A3 | 
        Address 3 | 
    
    
        | D12 | 
        A1 | 
        Address 1 | 
    
    
        | E1 | 
        D9 | 
        Data 9 | 
    
    
        | E2 | 
        D4 | 
        Data 4 | 
    
    
        | E3 | 
        D14 | 
        Data 14 | 
    
    
        | E4 | 
        BERR# | 
        Bus Error | 
    
    
        | E5 | 
        AM5 | 
          | 
    
    
        | E6 | 
        A22 | 
        Address 22 | 
    
    
        | E7 | 
        A20 | 
        Address 20 | 
    
    
        | E8 | 
        A17 | 
        Address 17 | 
    
    
        | E9 | 
        A7 | 
        Address 7 | 
    
    
        | E10 | 
        IRQ5# | 
        Interrupt 5 | 
    
    
        | E11 | 
        IRQ3# | 
        Interrupt 3 | 
    
    
        | E12 | 
        A8 | 
        Address 8 | 
    
ECB (Bottom)
    
        | Pin | 
        Name | 
        Description | 
    
    
        | A1 | 
        D5 | 
        Data 5 | 
    
    
        | A2 | 
        D2 | 
        Data 2 | 
    
    
        | A3 | 
        A4 | 
        Data 4 | 
    
    
        | A4 | 
        A7 | 
        Address 7 | 
    
    
        | A5 | 
        BAI | 
          | 
    
    
        | A6 | 
        2F | 
          | 
    
    
        | A7 | 
        A10 | 
        Address 10 | 
    
    
        | A8 | 
        INT# | 
          | 
    
    
        | A9 | 
        VCMOS | 
          | 
    
    
        | A10 | 
        PWRCLR# | 
          | 
    
    
        | A11 | 
        A13 | 
        Address 13 | 
    
    
        | A12 | 
        RESET# | 
        Reset | 
    
    
        | B1 | 
        D0 | 
        Data 0 | 
    
    
        | B2 | 
        D4 | 
        Data 4 | 
    
    
        | B3 | 
        A1 | 
        Address 1 | 
    
    
        | B4 | 
        WAIT# | 
          | 
    
    
        | B5 | 
        A17 | 
        Address 17 | 
    
    
        | B6 | 
        IEO | 
          | 
    
    
        | B7 | 
        n/c | 
        Not connected | 
    
    
        | B8 | 
        DMARDY | 
          | 
    
    
        | B9 | 
        RD# | 
        Read | 
    
    
        | B10 | 
        IORQ# | 
          | 
    
    
        | B11 | 
        ? | 
          | 
    
    
        | B12 | 
        n/c | 
        Not connected | 
    
    
        | C1 | 
        D6 | 
        Data 6 | 
    
    
        | C2 | 
        A0 | 
        Address 0 | 
    
    
        | C3 | 
        A5 | 
        Address 5 | 
    
    
        | C4 | 
        A16 | 
        Address 16 | 
    
    
        | C5 | 
        A18 | 
        Address 18 | 
    
    
        | C6 | 
        BAO | 
          | 
    
    
        | C7 | 
        M1# | 
          | 
    
    
        | C8 | 
        WR# | 
          | 
    
    
        | C9 | 
        n | 
          | 
    
    
        | C10 | 
        A12 | 
        Address 12 | 
    
    
        | C11 | 
        A9 | 
        Address 9 | 
    
    
        | C12 | 
        n/c | 
        Not connected | 
    
    
        | D1 | 
        D7 | 
        Data 7 | 
    
    
        | D2 | 
        A2 | 
        Address 2 | 
    
    
        | D3 | 
        A8 | 
        Address 8 | 
    
    
        | D4 | 
        BUSRQ# | 
          | 
    
    
        | D5 | 
        A19 | 
        Address 19 | 
    
    
        | D6 | 
        A11 | 
        Address 11 | 
    
    
        | D7 | 
        NMI# | 
        Non Maskable Interrupt | 
    
    
        | D8 | 
        PF | 
          | 
    
    
        | D9 | 
        HALT# | 
          | 
    
    
        | D10 | 
        RFSH# | 
          | 
    
    
        | D11 | 
        MRQ# | 
          | 
    
    
        | D12 | 
        n/c | 
        Not connected | 
    
    
        | E1 | 
        D3 | 
        Data 3 | 
    
    
        | E2 | 
        A3 | 
        Address 3 | 
    
    
        | E3 | 
        A6 | 
        Address 6 | 
    
    
        | E4 | 
        IEI | 
          | 
    
    
        | E5 | 
        D1 | 
        Data 1 | 
    
    
        | E6 | 
        A14 | 
        Address 14 | 
    
    
        | E7 | 
        n/c | 
        Not connected | 
    
    
        | E8 | 
        n/c | 
        Not connected | 
    
    
        | E9 | 
        DESLCT# | 
          | 
    
    
        | E10 | 
        A15 | 
        Address 15 | 
    
    
        | E11 | 
        BUSAK# | 
          | 
    
    
        | E12 | 
        n/c | 
        Not connected | 
    
SMP16 (Bottom)
    
        | Pin | 
        Name | 
        Description | 
    
    
        | A1 | 
        NMI# | 
        Non Maskable Interrupt | 
    
    
        | A2 | 
        IRQ0# | 
        Interrupt 0 | 
    
    
        | A3 | 
        D11 | 
        Data 11 | 
    
    
        | A4 | 
        D9 | 
        Data 9 | 
    
    
        | A5 | 
        RDYIN | 
          | 
    
    
        | A6 | 
        IOW# | 
          | 
    
    
        | A7 | 
        A15 | 
        Address 15 | 
    
    
        | A8 | 
        CLK | 
          | 
    
    
        | A9 | 
        A10 | 
        Address 10 | 
    
    
        | A10 | 
        A7 | 
        Address 7 | 
    
    
        | A11 | 
        TC/EOP# | 
          | 
    
    
        | A12 | 
        A2 | 
        Address 2 | 
    
    
        | B1 | 
        D15 | 
        Data 15 | 
    
    
        | B2 | 
        D13 | 
        Data 13 | 
    
    
        | B3 | 
        D3 | 
        Data 3 | 
    
    
        | B4 | 
        D1 | 
        Data 1 | 
    
    
        | B5 | 
        MEMW# | 
          | 
    
    
        | B6 | 
        A18 | 
        Address 18 | 
    
    
        | B7 | 
        A14 | 
        Address 14 | 
    
    
        | B8 | 
        DACKx# | 
          | 
    
    
        | B9 | 
        A9 | 
        Address 9 | 
    
    
        | B10 | 
        IRQ3# | 
        Interrupt 3 | 
    
    
        | B11 | 
        IOCS16# | 
          | 
    
    
        | B12 | 
        A1 | 
        Address 1 | 
    
    
        | C1 | 
        D7 | 
        Data 7 | 
    
    
        | C2 | 
        D5 | 
        Data 5 | 
    
    
        | C3 | 
        D10 | 
        Data 10 | 
    
    
        | C4 | 
        D8 | 
        Data 8 | 
    
    
        | C5 | 
        BUSEN | 
          | 
    
    
        | C6 | 
        IOR# | 
          | 
    
    
        | C7 | 
        A13 | 
        Address 13 | 
    
    
        | C8 | 
        A11 | 
        Address 11 | 
    
    
        | C9 | 
        IRQ1# | 
        Interrupt 1 | 
    
    
        | C10 | 
        A6 | 
        Address 6 | 
    
    
        | C11 | 
        A4 | 
        Address 4 | 
    
    
        | C12 | 
        IRQ4# | 
        Interrupt 4 | 
    
    
        | D1 | 
        D14 | 
        Data 14 | 
    
    
        | D2 | 
        D12 | 
        Data 12 | 
    
    
        | D3 | 
        D2 | 
        Data 2 | 
    
    
        | D4 | 
        D0 | 
        Data 0 | 
    
    
        | D5 | 
        MEMR# | 
          | 
    
    
        | D6 | 
        A17 | 
        Address 17 | 
    
    
        | D7 | 
        INTA# | 
          | 
    
    
        | D8 | 
        INT# | 
          | 
    
    
        | D9 | 
        A8 | 
        Address 8 | 
    
    
        | D10 | 
        MECS16# | 
          | 
    
    
        | D11 | 
        ALE | 
          | 
    
    
        | D12 | 
        A0 | 
        Address 0 | 
    
    
        | E1 | 
        D6 | 
        Data 6 | 
    
    
        | E2 | 
        D4 | 
        Data 4 | 
    
    
        | E3 | 
        MMIO# | 
          | 
    
    
        | E4 | 
        BHEN | 
          | 
    
    
        | E5 | 
        A19 | 
        Address 19 | 
    
    
        | E6 | 
        A16 | 
        Address 16 | 
    
    
        | E7 | 
        A12 | 
        Address 12 | 
    
    
        | E8 | 
        DRQx# | 
          | 
    
    
        | E9 | 
        IRQ2# | 
        Interrupt 2 | 
    
    
        | E10 | 
        A5 | 
        Address 5 | 
    
    
        | E11 | 
        A3 | 
        Address 3 | 
    
    
        | E12 | 
        IRQ5# | 
        Interrupt 5 | 
    
Floppy/EIDE (Bottom)
    
        | Pin | 
        Name | 
        Description | 
    
    
        | A1 | 
        FDSEL1 | 
        Floppy Select 1 | 
    
    
        | A2 | 
        FDSEL0 | 
        Floppy Select 0 | 
    
    
        | A3 | 
        FDME1 | 
        Floppy ? | 
    
    
        | A4 | 
        DIR | 
        Floppy Direction | 
    
    
        | A5 | 
        STEP | 
        Floppy Step | 
    
    
        | A6 | 
        WRDATA | 
        Floppy Write Data | 
    
    
        | A7 | 
        WE | 
        Floppy Write? | 
    
    
        | A8 | 
        TRK0 | 
        Floppy Track 0 | 
    
    
        | A9 | 
        WP | 
        Floppy Write? | 
    
    
        | A10 | 
        RDDATA | 
        Floppy ? | 
    
    
        | A11 | 
        HDSEL | 
        Floppy HD Select | 
    
    
        | A12 | 
        DSKCHG | 
        Floppy DiskChange | 
    
    
        | B1 | 
        DRVDEN1 | 
        ? | 
    
    
        | B2 | 
        DRVDEN0 | 
        ? | 
    
    
        | B3 | 
        IDECS3P# | 
        IDE ? | 
    
    
        | B4 | 
        IDEA2 | 
        IDE ? | 
    
    
        | B5 | 
        IDEIRQS | 
        IDE ? | 
    
    
        | B6 | 
        IDEPUS | 
        IDE ? | 
    
    
        | B7 | 
        IDEDRQP | 
        IDE ? | 
    
    
        | B8 | 
        IDED14 | 
        IDE Data 14 | 
    
    
        | B9 | 
        IDED8 | 
        IDE Data 8 | 
    
    
        | B10 | 
        IDED6 | 
        IDE Data 6 | 
    
    
        | B11 | 
        IDED11 | 
        IDE Data 11 | 
    
    
        | B12 | 
        IDED3 | 
        IDE Data 3 | 
    
    
        | C1 | 
        FDME0 | 
        Floppy Me? | 
    
    
        | C2 | 
        INDX | 
        Floppy Index | 
    
    
        | C3 | 
        IDECS3S# | 
        IDE ? | 
    
    
        | C4 | 
        IDEA0 | 
        IDE ? | 
    
    
        | C5 | 
        IDEDAKS# | 
        IDE ? | 
    
    
        | C6 | 
        IDEIOR# | 
        IDE ? | 
    
    
        | C7 | 
        IDEDRQS | 
        IDE ? | 
    
    
        | C8 | 
        IDED1 | 
        IDE Data 1 | 
    
    
        | C9 | 
        #IDERST | 
        IDE ? | 
    
    
        | C10 | 
        IDED10 | 
        IDE Data 10 | 
    
    
        | C11 | 
        IDED4 | 
        IDE Data 4 | 
    
    
        | C12 | 
        IDED2 | 
        IDE Data 2 | 
    
    
        | D1 | 
        IDELEDS# | 
        IDE LED ? | 
    
    
        | D2 | 
        IDELEDP# | 
        IDE LED ? | 
    
    
        | D3 | 
        IDECS1S# | 
        IDE ? | 
    
    
        | D4 | 
        IDEIRQP | 
        IDE ? | 
    
    
        | D5 | 
        IDEPUP | 
        IDE Pull Up ? | 
    
    
        | D6 | 
        IDEIOW# | 
        IDE ? | 
    
    
        | D7 | 
        IDED15 | 
        IDE Data 15 | 
    
    
        | D8 | 
        IDED13 | 
        IDE Data 13 | 
    
    
        | D9 | 
        IDED7 | 
        IDE Data 7 | 
    
    
        | D10 | 
        GND | 
        Ground | 
    
    
        | D11 | 
        GND | 
        Ground | 
    
    
        | D12 | 
        GND | 
        Ground | 
    
    
        | E1 | 
        GND | 
        Ground | 
    
    
        | E2 | 
        GND | 
        Ground | 
    
    
        | E3 | 
        IDECS1P# | 
        IDE ? | 
    
    
        | E4 | 
        IDEA1 | 
        IDE ? | 
    
    
        | E5 | 
        IDEDAKP# | 
        IDE ? | 
    
    
        | E6 | 
        IDEIORDY | 
        IDE ? | 
    
    
        | E7 | 
        IDED0 | 
        IDE Data 0 | 
    
    
        | E8 | 
        IDED12 | 
        IDE Data 12 | 
    
    
        | E9 | 
        IDED9 | 
        IDE Data 9 | 
    
    
        | E10 | 
        IDED5 | 
        IDE Data 5 | 
    
    
        | E11 | 
        GND | 
        Ground | 
    
    
        | E12 | 
        GND | 
        Ground | 
    
SCSI (Bottom)
    
        | Pin | 
        Name | 
        Description | 
    
    
        | A1 | 
        TERM | 
          | 
    
    
        | A2 | 
        GND | 
        Ground | 
    
    
        | A3 | 
        I/O# | 
          | 
    
    
        | A4 | 
        REQ# | 
          | 
    
    
        | A5 | 
        ATN# | 
          | 
    
    
        | A6 | 
        D8 | 
        Data 8 | 
    
    
        | A7 | 
        D9 | 
        Data 9 | 
    
    
        | A8 | 
        D10 | 
        Data 10 | 
    
    
        | A9 | 
        D2 | 
        Data 2 | 
    
    
        | A10 | 
        D4 | 
        Data 4 | 
    
    
        | A11 | 
        DP0 | 
          | 
    
    
        | A12 | 
        GND | 
        Ground | 
    
    
        | B1 | 
        TERM | 
          | 
    
    
        | B2 | 
        GND | 
        Ground | 
    
    
        | B3 | 
        GND | 
        Ground | 
    
    
        | B4 | 
        GND | 
        Ground | 
    
    
        | B5 | 
        GND | 
        Ground | 
    
    
        | B6 | 
        GND | 
        Ground | 
    
    
        | B7 | 
        GND | 
        Ground | 
    
    
        | B8 | 
        GND | 
        Ground | 
    
    
        | B9 | 
        GND | 
        Ground | 
    
    
        | B10 | 
        GND | 
        Ground | 
    
    
        | B11 | 
        GND | 
        Ground | 
    
    
        | B12 | 
        GND | 
        Ground | 
    
    
        | C1 | 
        TERM | 
          | 
    
    
        | C2 | 
        GND | 
        Ground | 
    
    
        | C3 | 
        C/D# | 
          | 
    
    
        | C4 | 
        MSG# | 
          | 
    
    
        | C5 | 
        ACK# | 
          | 
    
    
        | C6 | 
        D12 | 
        Data 12 | 
    
    
        | C7 | 
        DP1 | 
        Data P1 | 
    
    
        | C8 | 
        D13 | 
        Data 13 | 
    
    
        | C9 | 
        D1 | 
        Data 1 | 
    
    
        | C10 | 
        D5 | 
        Data 5 | 
    
    
        | C11 | 
        D7 | 
        Data 7 | 
    
    
        | C12 | 
        GND | 
        Ground | 
    
    
        | D1 | 
        TERM | 
          | 
    
    
        | D2 | 
        GND | 
        Ground | 
    
    
        | D3 | 
        GND | 
        Ground | 
    
    
        | D4 | 
        GND | 
        Ground | 
    
    
        | D5 | 
        GND | 
        Ground | 
    
    
        | D6 | 
        GND | 
        Ground | 
    
    
        | D7 | 
        GND | 
        Ground | 
    
    
        | D8 | 
        GND | 
        Ground | 
    
    
        | D9 | 
        GND | 
        Ground | 
    
    
        | D10 | 
        GND | 
        Ground | 
    
    
        | D11 | 
        GND | 
        Ground | 
    
    
        | D12 | 
        GND | 
        Ground | 
    
    
        | E1 | 
        TERM | 
          | 
    
    
        | E2 | 
        GND | 
        Ground | 
    
    
        | E3 | 
        SEL# | 
          | 
    
    
        | E4 | 
        RST# | 
          | 
    
    
        | E5 | 
        BSY# | 
          | 
    
    
        | E6 | 
        D14 | 
        Data 14 | 
    
    
        | E7 | 
        D15 | 
        Data 15 | 
    
    
        | E8 | 
        D11 | 
        Data 11 | 
    
    
        | E9 | 
        D0 | 
        Data 0 | 
    
    
        | E10 | 
        D3 | 
        Data 3 | 
    
    
        | E11 | 
        D6 | 
        Data 6 | 
    
    
        | E12 | 
        GND | 
        Ground | 
    
    Contributor: Joakim Ögren
    Sources: IndustrialPCI
    page at Standard Industrial
    PC Systems's (SIPS) homepage 